CH250 - 2P 50A 240V Breaker

Eaton Cutler-Hammer

  • $27.47 (Each)
  • $27.47 (Each)

  • $137.35 (Per 5)

  • $686.75 (Per 25)

Availability: Currently Out Of Stock

QTY:
Each
Quick Specs
Catalog Number
CH250
Manufacturer
Eaton Cutler-Hammer
Manufacturer's Part Number
CH250
Description
2P 50A 240V Breaker
Standard Trip Circuit Breaker, 50 A, Common Tripping Mechanism, Plug-On, 120/240 V Ac, 2.5 In Overall Height, 2 In Overall Length, 1 In Overall Width, 0.56 LB
Slang Terms

Categories
Standard Trip Plug - 2 Pole Standard Trip Plug-In
Classification
Loadcenter Plug In Breakers and Accessories
UNSPSC
39121603 - Miniature circuit breakers
UPC/GTIN
782113101859 / 00782113101859
Weight per unit
0.56 (lbs/each)
Price & Packaging
Minimum Order Quantity
1
Unit
$27.47 (Each)
Carton
$137.35 (Per 5)
Standard Packaging
$686.75 (Per 25)
Resources
Images
 
 
CH250 - Small Image
 
CH250 - Large Image
 
CH250 - Large Image
 
CH250 - Large Image
Attachments
 
 
CH250 - Specification Sheet
Brochures
 
 
CH250 - Brochure
Other Links
 
 
CH250 - Other
Features
Current Rating
50 A
Voltage Rating
120/240 V ac
interrupt rating
10 kAIC
amperage rating
50
used with
Type CH Loadcenters
Wire Size
#14-2 AWG Cu/Al 60°C or 75°C
Poles
2
Dimensions and Weight
Overall Length
2 in
Height
2.5
Width
1
Length
2
Descriptions
Product Type
Standard Trip Circuit Breaker
Description
2P 50A 240V BREAKER
Long Description
Standard Trip Circuit Breaker, 50 A, Common Tripping Mechanism, Plug-On, 120/240 V ac, 2.5 in Overall Height, 2 in Overall Length, 1 in Overall Width, 0.56 lb
Features
Quick-make, quick-break switch mechanism combined with inverse time element tripping operation and trip- free handle design. Type CH circuit breakers trip to the OFF position, eliminating nuisance callbacks. The CHF family also includes a trip flag to differentiate between a trip and the breaker being turned off. The thermal-magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions. Multipole breakers have internal common trip co
Short Description
2P Standard Trip Circuit Breaker, 50 A, 120/240 VAC w/Trip Flag
Additional Information
circuit breaker type
Standard Trip Circuit Breaker
Tripping Mechanism
Common
Mounting Type
Plug-On
Overall Height
2.5 in
Overall Width
1 in
for use with
Type CH Loadcenters
Standards Met
UL 489 Listed;IGCC 4897
Trip Type
Common
Manufacturer Information
Brand
EATON CUTLER-HAMMER
Manufacturers Part Number
CH250
GTIN
00782113101859
UPC
782113101859
Taxonomies, Classifications, and Categories
Category Description
Loadcenter Plug In Breakers and Accessories
unspsc code
39121603
igcc
4897
Type
Type CH 3/4-inch Standard Circuit Breaker
Availability
Manufacturer Status
Inactive
Packaging
Weight
0.56 lb
Weight per each
0.56
Carton
5
Package
25
Uses, Certifications, and Standards
Application
Circuit Protection
standard
UL 489
You must have an account to view stock levels

* All prices subject to change.